Standard operating procedure · UGV-001

Eleven steps. Five phases. One defensible record.

Underground pipe and sewer CCTV inspection follows a fixed sequence — so that the data is comparable between sites, crews and years.

The five inspection phases

  • Planning

    Desktop study and GIS verification before anyone leaves the office.

  • Setup

    Safety perimeter, PPE and calibrated equipment at the manhole.

  • Manhole survey

    Cover lifted, chamber ventilated, depth measured, walls filmed.

  • Mainline survey

    Crawler deployed, driven and logged metre by metre.

  • Deliverables

    Media archived, defects coded, report issued and explained.

Phase 01

Pre-site planning & data analysis

Most inspection problems are decided before the crew arrives. We spend the first phase making sure the right pipe is being surveyed for the right reason.

Output: a verified inspection plan with target manholes, pipe schedule and access requirements.

01
Desktop study

Read and review site data

Historical maintenance logs, structural drawings and known pipe diameters are reviewed before dispatch. Target materials (RCC, PVC, masonry) and expected flow levels are identified, and zones of concern are marked.

02
GIS analysis

GIS mapping and spatial verification

Utility layouts are overlaid in GIS to confirm network geometry. Manhole coordinates (X, Y, Z) and upstream/downstream flow directions are cross-checked, and the field route, parking, equipment access and traffic zones are planned.

Phase 02

On-site setup & safety deployment

A drainage inspection happens in live public space. The perimeter goes up before the manhole comes open — no exceptions.

Safety priority: PPE, barriers and ventilation are mandatory on every job, regardless of pipe size or depth.

03
Safety

Go to site and deploy safety equipment

The work area is mobilised with a mandatory safety perimeter: traffic cones, barriers, caution tape and warning signage around the manhole. Full PPE — helmets, high-visibility vests, gloves and steel-toe boots — is worn before any cover is lifted.

04
Hardware

Join and assemble all inspection equipment

Control unit, reel system, monitor and power are assembled and connected. System boot check, LED intensity test and camera focus calibration are completed, and data storage plus live telemetry are confirmed before deployment.

Phase 03

Manhole operations & periscope inspection

The chamber is an asset in its own right. Before the mainline is touched, the manhole is opened safely, measured and recorded in 360°.

360° vertical inspection: the periscope captures chamber walls, drop pipes, benching and both pipe barrels from the surface.

05
Access

Safely open the manhole

The cover is unsealed and lifted with mechanical cover lifters or magnetic pullers — never by manual spinal lift. A mandatory forced ventilation period of 5–10 minutes dissipates toxic gases, and the rim, benching and frame integrity are checked immediately on opening.

06
Survey

Measure manhole depth and invert level

Precise measurements are taken from the cover frame down to the pipe invert using calibrated rods or a laser distance meter. Ground elevation, manhole depth, invert depth and water level are recorded, along with initial structural conditions such as a brick drop, displaced benching or root ingress.

07
360° vertical

Lower the periscope and record photos and video

The HD camera is lowered vertically into the chamber to capture deep structural visuals. A 360° HD video of walls, drop pipes and benching is recorded, targeted high-resolution stills of leaks, cracks and silt build-up are taken, and a line-of-sight check is made into the incoming and outgoing barrels.

Phase 04

Mainline crawler inspection

The crawler only goes in when the pipe can take it. Diameter, silt level and flow decide whether a mainline survey is safe and meaningful.

Controlled speed: the crawler runs at a maximum of 0.15 m/s so that footage stays stable and no defect is skipped.

08
Mainline

Deploy the crawler and inspect the pipeline

Wheel size is matched to the pipe diameter and internal flow height. The crawler is lowered onto the invert with the crane arm and aligned to the pipe centreline, then driven at a steady speed while continuous HD video is recorded. Chainage is logged for structural defects, cracks, joint displacement and debris.

Phase 05

Data processing & final deliverables

The survey is not finished when the crawler comes out. It is finished when the client can act on it.

Handover package: printed bound report plus a USB drive containing the video and photo evidence.

09
Data transfer

Extract photos and video to USB

Inspection media is retrieved from control-unit storage and archived to high-speed USB media. Raw HD video (.MP4 / .AVI) and photo snapshots (.JPG) are exported into a structured directory by site, manhole and equipment, and file integrity is verified on an external viewer before site clearance.

10
Reporting

Generate the comprehensive inspection report

Field observations, depth logs, GIS coordinates and visual defect logs are compiled into a formal engineering report. Defects are coded by classification, snapshot images are linked to exact metre marks, and a manhole inspection sheet with depth profiles and invert elevations is included.

11
Handover

Client delivery and executive conclusion

The official package is handed over with actionable engineering conclusions — for example high-pressure jetting required, trenchless CIPP lining, structural repair, or routine monitoring — supported by the evidence behind each recommendation.

Sequence summary

The workflow at a glance

Inspection workflow summary by step, stage, equipment and output
Steps Stage Primary tool / equipment Key output
01 – 02 Pre-site review GIS tools, site maps Verified coordinates & plan
03 – 04 On-site preparation PPE, cones, control unit Safe & calibrated setup
05 – 07 Vertical survey Periscope, depth rods Invert depth & chamber video
08 Line crawl Crawler system Continuous footage & defect log
09 – 11 Delivery USB media & report Client report & conclusion
Field reality

What changes when the site says no

The procedure is fixed. The site is not. When conditions prevent a reliable survey, we stop, record why, and specify what has to change — rather than producing footage that misrepresents the asset.

See how this played out on site
High water level

Submerged crowns restrict visibility. Action: periscope survey at peak flow for a first look, crawler inspection during a controlled low-flow window.

Heavy silt and debris

Dense deposits hide the invert and stop the crawler. Action: high-pressure jetting or suction before deployment, scoped and quoted separately.

Blockages and obstructions

Partial or complete blockages prevent travel. Action: record the obstruction's extent and position accurately, clear access, then re-inspect.

Damaged or collapsed pipe

Cracks, breaks and collapse stop the camera. Action: 360° HD capture of the failure, precise chainage, and a structural repair recommendation before continuation.

Difficult manhole access

Deep, flooded or buried chambers make deployment hard. Action: surface-controlled winch deployment, or excavation and desilting where the cover is buried.

Traffic and weather

Congestion needs coordinated permissions; monsoon surges raise flow. Action: inspection scheduled into seasonal low-flow windows and approved traffic windows.

Want the full SOP for your records?

We can issue the complete operating procedure as a PDF for your tender or work-order file.